lobbyTO

Committee of Adjustment application · Minor variance (MV)

Committee of Adjustment application A0482/26TEY

1375 Queen St W

Status
Closed
Approved
Submitted
18 June 2026
No appeal recorded
Linked lobbying registrations
0
None published
Communications on linked registrations
0

Application record

Type
Minor variance (MV)
Addresses
1375 Queen St W
Ward
Ward 4 · Gord Perks
Submitted
18 June 2026
Status
Closed
Outcome recorded
Approved
Hearing date
19 August 2026
Decision
Approved
Objection at the hearing
Not recorded
Appealed
No appeal recorded

Source: City of Toronto open data (Development Applications; Committee of Adjustment Applications). Dataset page

Description

To alter the development standards for the mixed-use development which is currently under construction, ((approved as 8-storeys under Site Specific Zoning By-law 413-2024(OLT)), and increased to 9-storeys ((29.41 m in building height) excluding the Mechanical Penthouse, as approved under Minor Variance Decision A0905/24TEY)) by currently increasing the building height to 10-storeys ((33.46 m in building height) including the Mechanical Penthouse, and one new residential unit)), increasing the maximum gross floor area, altering the minimum building setbacks, and reducing the indoor and outdoor amenity spaces, beyond recently approved Minor Variance Decision A0905/24TEY. Also, there will be a total of 63 residential dwelling units on this lot (50 rental dwelling units and 13 affordable housing units). A related Site Plan Control Application (File Number 20 21 251366 STE 04 SA) is currently under review.

Linked lobbying registrations

No published lobbying registrations are linked to this application.

Other registrations that mention this application's addresses

Text matches on the address only. They are not linked to this application unless listed above.

None.

Comparison with similar applications

Lobbied applications are compared only with unlobbied applications of the same type, in the same ward, submitted in the same year and of the same size band (units or floor area from the description; sub-type for Committee of Adjustment files). Unlobbied applications are weighted to match the lobbied group. Raw lobbied versus unlobbied averages are not reported.

Minor variance (MV), Ward 4

8 lobbied · 130 matched

Hidden: fewer than 20 applications in the lobbied or the matched unlobbied group.

Minor variance (MV), City-wide

173 lobbied · 3,646 matched

Median days

  • Lobbied126
  • Matched, unlobbied114

Approval rate

  • Lobbied75% n=154
  • Matched, unlobbied91% n=3,058

Refusal rate

  • Lobbied25%
  • Matched, unlobbied9%

Appeal rate

  • Lobbied19%
  • Matched, unlobbied4%

Objection rate

  • Lobbied43%
  • Matched, unlobbied27%
Data table· 4 rows
Minor variance (MV), Ward 4: 8 lobbied and 130 matched unlobbied applications in 6 matched strata
GroupnMedian daysApproval rateRefusal rateAppeal rateObjection rate
Lobbied8Hidden: fewer than 20 applications in the lobbied or the matched unlobbied group.
Matched, unlobbied130Hidden: fewer than 20 applications in the lobbied or the matched unlobbied group.
Minor variance (MV), City-wide: 173 lobbied and 3,646 matched unlobbied applications in 103 matched strata
GroupnMedian daysApproval rateRefusal rateAppeal rateObjection rate
Lobbied17312675% (n=154)25%19%43%
Matched, unlobbied3,64611491% (n=3,058)9%4%27%

Submission to hearing. Approval and refusal rates are among applications with a recorded decision.

Large and complex applications attract both lobbying and longer reviews, and matching cannot remove every difference between applications, so a difference does not show that lobbying changed how an application was reviewed.

Lobbyists choose whom to contact, so a difference does not show a change of mind.